Static analysis of guyed tower regarding cable sagging by using finite difference model
الموضوعات : فصلنامه شبیه سازی و تحلیل تکنولوژی های نوین در مهندسی مکانیکKaveh Kumarci 1 , Alireza Baharizadeh 2
1 - college of skills and entrepreneurship, shahrekord branch, Islamic Azad University, Shahrekord, Iran
2 - College of skills and entrepreneurship, shahrekord branch, Islamic Azad Univercity, Shahrekord, Iran
الکلمات المفتاحية: Static Analysis, finite difference method, Guyed cable, Cable sagging,
ملخص المقالة :
The static analysis of guyed towers is very complex because of high degree of non-linearity they exhibit due to their slender and flexibility. In the static analysis of cable systems, due to the effects of nonlinearity of loading and large functions, the interference of loads and displacement have no much value. Because of having no analytical solution for these systems, numerical methods have been applied. Finite difference method (FDM) is one of the known methods which are directly related to nonlinear relative equations and, the cable system is defined using calculating of them and deformation equations . In this research, the non-linear analysis of cables under three dimension static loads is analyses using FDM. This model can be analyzed three dimension response of cable using sequential method. In this model, long and inclined pre-tensioned cables have been studied in which only axial stiffness of cable is considered while bending and torsion stiffness are assumed to be negligible.
[1] Ghodrati Amiri, G. (1997). Seismic sensitivity of tall guyed telecommunication towers
[2] Honary, M., Vaez Shoushtari, A., & Jaberzadeh, E. (2021). Assessing the vulnerability of Shiekh Bahaei’s bath under the blast wave. Journal of Simulation and Analysis of Novel Technologies in Mechanical Engineering, 13(2), 39-46.
[3] Khanahmadi, R., Hashemian, M., & Pirmoradian, M. (2021). Dynamic stability analysis of functionally graded Euler-Bernoulli nanobeams under a sequence of moving nanoparticle based on nonlocal elasticity theory. Journal of Simulation and Analysis of Novel Technologies in Mechanical Engineering, 13(2), 25-38.
[4] Shi, H., & Salim, H. (2015). Geometric nonlinear static and dynamic analysis of guyed towers using fully nonlinear element formulations. Engineering Structures, 99, 492-501.
[5] Kogul, S., Gunathilaka, A. M. L. N., Lewanagamage, C. S., & Jayasinghe, M. T. R. (2015). Seismic Analysis of Guyed Mast Towers in Sri Lanka.
[6] Hasanlu, M., Mirhosseini, S. G., Sadeghzadeh, M., & Bagheri, A. Modal Analysis Turboshaft Test Stand Motor Designed by Using ANSYS. Journal of Simulation and Analysis of Novel Technologies in Mechanical Engineering, 10(1), 781-796.
[7] Wahba, Y. M. (1999). Static and dynamic analyses of guyed antenna towers.
[8] Madenci, E., & Guven, I. (2015). The finite element method and applications in engineering using ANSYS®. Springer.
[9] Mahboubi Shad, A., & Esfahanian, M. (2008). Static and Dynamic Analysis of Bus Structure and Chassis of O-457. Journal of Simulation and Analysis of Novel Technologies in Mechanical Engineering, 1(1), 67-76.
[10] Davenport, A. G., & Steels, G. N. (1965). Dynamic behavior of massive guy cables. Journal of the Structural Division, 91(2), 43-70.
[11] Zhang, L. F., Liu, X. H., & Yan, B. (2015). The influence of sag on vibration modal of suspended cable. In Applied Mechanics and Materials (Vol. 724, pp. 242-249). Trans Tech Publications Ltd.
[12] Ghafari Osgoie, M. (2013). Validation of seismic response prediction of a guyed telecommunication mast with ambient vibration measurements.