A novel sensor based on a heterocyclic ionophore for cerium (III) analysis in real samples
الموضوعات : International Journal of Heterocyclic ChemistryArezoo Ghaemi 1 , Haman Tavakkoli 2 , Fariba Mehranfar 3
1 - Department of Chemistry, Ahvaz Branch, Islamic Azad University,
Ahvaz, Iran
2 - Department of Chemistry, Ahvaz Branch, Islamic Azad University,
Ahvaz, Iran
3 - Department of Chemistry, Ahvaz Branch, Islamic Azad University,
Ahvaz, Iran
الکلمات المفتاحية: Potentiometry, PVC membrane, Cerium (III) selective sensor, Kryptofix22DD,
ملخص المقالة :
A new polyvinyl choloride (PVC) membrane sensor for cerium(III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensorexhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with aNernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two monthswithout any considerable divergence in its potential. The proposedsensor revealed high selectivity toward Ce3+ ion with respect to somealkali, alkaline earth and transition metal cations. It could be used in awide pH range of 2.0-11.0. The sensor was successfully used as anindicator electrode in potentiometric titration of Ce3+ ion withethylenediaminetetraacetic acid (EDTA) and sodium iodide (NaI)solutions, and in determination of Ce (III) concentration in real samples.
[1] C. L. Wilson, D. W. Wilson, Comprehensive Analytical Chemistry, vol. 1C, Elsevier,
Amsterdam (1962) p. 477.
[2] D. Ammann, W. E. Morf, P. Anker, P. C. Meier, E. Pretsch, W. Simon, Ion-Sel. Electrode
Rev. 5 (1983) 3.
[3] M. E. Mayerhoff, M. N. Opdycke, Adv. Clin. Chem. 26 (1986) 1.
[4] S. Li-Xian, T. Okada, J. P. Collin, H. Sugihara, Anal. Chim. Acta. 329 (1996) 57.
[5] A. Kumar, S. K. Mittal, Sens. Actuators B 99 (2004) 340.
[6] A. K. Singh, S. Mehtab, Talanta 74 (2008) 806.
[7] B. H. Freitas, F. A. Amaral, N. Bocchi, M. F. S. Teixeira, Electrochim. Acta 55 (2010) 5659.
[8] H. A. Zamani, M. R. Ganjali, P. Norouzi, A. Tadjarodi, E. Shahsavani, Mater. Sci. Eng. C 28
(2008) 1489.
[9] G. H. Rounaghi, R. Mohammad Zadeh Kakhki, H. Sadeghian, Electrochim. Acta 56 (2011)
9756.
[10] A. Ghaemi, H. Tavakkoli, T. Mombeni, Mater. Sci. Eng. C 38 (2014) 186.
[11] E. Weber, S. Patai, Z. Rapport, Crown Ether and Analogues, Wiley, New York (1989) p.
305.
[12] Z. Q. Li, Z. Y. Wu, R. Yuan, M. Ying, G. L. Shen, R. Q. Yu, Electrochim. Acta 44 (1999)
2543.
[13] A. Ruhollahi, M. Shamsipur, Anal. Chem. 71 (1999) 1350.
[14] I. H. A. Badr, M. Diaz, M. F. Hawthorne, L. G. Bachas, Anal. Chem. 71 (1999) 1371.
[15] T. Rosatzin, E. Bakker, Y. Suzuki, W. Simon, Anal. Chim. Acta 280 (1993) 197.
[16] H. A. Zamani, M. R. Ganjali, M. Adib, Sensor Lett. 4 (2006) 345.
[17] P. Buhlmann, E. Pretsch, E. Bakker, Chem. Rev. 98 (1998) 1593.
[18] D. Ammann, E. Pretsch, W. Simom, E. Lindner, A. Bezegh, E. Pungor, Anal. Chim. Acta
171 (1985) 119.
[19] T. S. Ma, S. S.M. Hassan, Organic Analysis Using Ion-Selective Electrodes, vols. 1 and 2,
Academic Press, London (1982).
[20] Y. Umezawa, P. Buhlmann, K. Umezawa, K. Tohda, S. Amemiya, Pure Appl. Chem. 72
(2000) 1851.