    1 - Presenting a New Fault Current Limiter Structure to Reduce the Over-voltage of the DFIG DC Link in the Voltage Sag Condition
    Journal of Applied Dynamic Systems and Control , Issue 1 , Year , Spring 2022
    In this study a new type of fault current limiter is introduced. It has been named multi-functional capacitive fault current limiter (MCFCL). as a variable capacitor, its function is to control active power flow in normal conditions as well as improving the capability o More
    In this study a new type of fault current limiter is introduced. It has been named multi-functional capacitive fault current limiter (MCFCL). as a variable capacitor, its function is to control active power flow in normal conditions as well as improving the capability of low voltage rid-through (LVRT) in fault operating conditions. The new structure has been proposed based on the capacitive bridge-type fault current limiter (BFCL) and the RL-type fault current limiter (FCL), which is modified to enhance low-voltage ride-through capability. To assess the efficacy of proposed fault current limiter, the time domain simulations were executed in PSCAD/EMTDC software and its function is compared with the RL-type SSFCLs in normal and symmetrical or asymmetrical fault conditions. Also its efficacy has been evaluated in a fixed speed based wind farm. The result of simulations showed that the MCFCL is not only able to control the power flow in normal operating condition, but also improves the LVRT performance in fault operating condition in the wind farms. Manuscript profile

  • Article

    2 - A Novel Multi-Functional Capacitive Fault Current Limiter to Enhance LVRT Capability of Wind Farm
    Journal of Applied Dynamic Systems and Control , Issue 1 , Year , Winter 2022
    In this study a new type of fault current limiter is introduced. It has been named multi-functional capacitive fault current limiter (MCFCL). as a variable capacitor, its function is to control active power flow in normal conditions as well as improving the capability o More
    In this study a new type of fault current limiter is introduced. It has been named multi-functional capacitive fault current limiter (MCFCL). as a variable capacitor, its function is to control active power flow in normal conditions as well as improving the capability of low voltage rid-through (LVRT) in fault operating conditions. The new structure has been proposed based on the capacitive bridge-type fault current limiter (BFCL) and the RL-type fault current limiter (FCL), which is modified to enhance low-voltage ride-through capability. To assess the efficacy of proposed fault current limiter, the time domain simulations were executed in PSCAD/EMTDC software and its function is compared with the RL-type SSFCLs in normal and symmetrical or asymmetrical fault conditions. Also its efficacy has been evaluated in a fixed speed based wind farm. The result of simulations showed that the MCFCL is not only able to control the power flow in normal operating condition, but also improves the LVRT performance in fault operating condition in the wind farms. Manuscript profile

  • Article

    3 - Impact of Load Shifting on the Profit of Electricity Retailer based on Demand Response and Risk Management
    Signal Processing and Renewable Energy , Issue 5 , Year , Autumn 2018
    This paper aims to describe the role of electricity retailer in power market for persuading consumer to shift their loads. It presents the influence of load shifting on retailer profit and risk management in market environment. In this problem, retailer participates in More
    This paper aims to describe the role of electricity retailer in power market for persuading consumer to shift their loads. It presents the influence of load shifting on retailer profit and risk management in market environment. In this problem, retailer participates in bilateral contract, also stochastic programming is used to manage the uncertainties of pool prices and elasticity of consumer. It shows that by participating retailer in market contract, the retailer profit will be changed. This paper also analyzes the consumer behavior when the load is shifted from the time with high price to the time with low price. The tariff of demand response program used in this paper is Time of use pricing for the periods of week. Risk Measuring is done by Value at Risk (VaR) and Conditional Value at Risk (CVaR) in this study. Manuscript profile